Suzuki Grand Vitara SQ416/SQ420/420WD

Since 1998 of release

Repair and car operation



Suzuka Grandee Vitara
- The general information
   + Safety measures
   The basic safety measures
   Safety measures at work with the catalyst
   Safety measures at service of electric chains
   + Procedure of check of electric chains
   Interrupting or weak connection
   Safety measures at installation of means of a mobile communication
   + The identification information
   Warning, warning and information labels
   Places of lifting of the car
   The list of the reductions used in the given management
   + The metric information
   The standard moments of inhalings
+ Maintenance service and greasing
+ Heater, ventilation and the conditioner
+ Steering
+ Suspension bracket
+ Wheels and tyres
+ Forward приводной a shaft shaft/bearing. An oil epiploon
+ Kardannye shaft
+ Brake system
+ Engines
+ Fuel system
+ Ignition system
+ Start system
+ Release system
+ Transmissions
+ Coupling
+ Transfer
+ Forward and back differentials
+ Windows, mirrors, locks and security measures. An immobilizer
+ Electric equipment







e8f2b5b1

Interrupting or weak connection

The majority of problems with intermittence of connection are connected with defect electric коннекторов or conductings though заедающее the relay or the solenoid can sometimes cause. At check of reliability of connection, carefully check up suspicious sites on:

  • Unreliable connection in коннекторе, or contacts not completely sit in the case коннектора (not on the place).
  • Dirt or corrosion traces on contacts. Contacts should be pure and on them there should not be the extraneous material complicating contact. Nevertheless, cleaning of contacts by an emery paper or similar materials is forbidden.
  • Case damage коннектора, the caused hit of a moisture and a dirt on contact also negatively affects on interfaced коннекторе.
  • The bent or damaged contacts. Check up each contact in коннекторе a problem site of a chain on good зажимание contact, using стыковочный contact. If зажимание contact insufficient draw in or replace contact.

 PERFORMANCE ORDER

  1. Check up pressure in contacts by their connection and separation.
  2. Be convinced of that contacts have been combined.
  • Bad connection the plug-wire.

Check up each wire of a problem site of a chain on weak connection, slightly having stirred his hands. At defect detection, repair or replace.
  • The ground isolation of a wire periodically causing short circuit, at a contact of the bared sites with other wires or body parts.
  • Breakage of a wire in isolation.

In this case chain check on indissolubility can yield positive results but if only one or two veins of a multicore cable are not damaged, resistance should be much more above. At failure detection repair or replace.