- The generator
Removal
Installation
Dismantling [Type 60 A]
Dismantling [Type 70 A and 80 A]
Survey [Type 60 A]
Survey [Type 70 A and 80 A]
Replacement of brushes
Assemblage [Type 60 A]
Assemblage [Type 70 A and 80 A]
+ Specifications
The inhaling moments
+ Tools/information for drivers
|
Survey [Type 60 A]
Rotor
|
- Using an ohmmeter, check up electroconductivity between contact rings of a rotor. If there is no electroconductivity, replace a rotor. Standard resistance: 2.5 - 2.9.
- Using an ohmmeter, check up, whether there is no electroconductivity between a contact ring and the rotor core. If there is an electroconductivity, replace a rotor.
- Check up contact rings, whether there is no roughness or a deposit. If they rough or are a deposit, replace a rotor.
|
|
Статор
|
- Using an ohmmeter, check up electroconductivity of all contacts. If there is no electroconductivity, replace статор.
- Using an ohmmeter, whether check up there is no electroconductivity between contacts of the coil and the core статора. If there is no electroconductivity, replace статор.
|
1 — статор 2 — contact статора |
|
|
Brush and щеткодержатель
|
- Check up each brush on deterioration, having measured its length.
|
- If the brush is worn out to a limit, replace a brush.
- Length of a brush "a"
- The standard: 16 mm (0.63 inches)
- Limit: 2 mm (0.08 inches)
|
|
|
The rectifier
|
- Using an ohmmeter, check up electroconductivity between cases of the top and bottom rectifiers and contact of each diode.
- Check up both directions, having changed щупы an ohmmeter. In each case there should be only unilateral conductivity. If result of check unsatisfactory, replace the rectifier.
|
- Check up unilateral electroconductivity between contacts and three diodes similarly described in item 1.
|
|
1 — the rectifier 2 — diode contact |
|
|
The condenser
Check up condenser capacity. Condenser capacity: 0.5 µF.
|
1 — the rectifier 2 — the condenser |
|
|