Suzuka Grandee Vitara
+ The general information
+ Maintenance service and greasing
+ Heater, ventilation and the conditioner
+ Steering
+ Suspension bracket
+ Wheels and tyres
+ Forward приводной a shaft shaft/bearing. An oil epiploon
+ Kardannye shaft
+ Brake system
+ Engines
+ Fuel system
+ Ignition system
+ Start system
+ Release system
+ Transmissions
+ Coupling
+ Transfer
+ Forward and back differentials
+ Windows, mirrors, locks and security measures. An immobilizer
- Electric equipment
+ Body electric equipment
+ Illumination system
- Electric equipment system
+ The general description
+ Diagnostics
+ The works made on the car
- Major repairs
- The generator
Removal
Installation
Dismantling [Type 60 A]
Dismantling [Type 70 A and 80 A]
Survey [Type 60 A]
Survey [Type 70 A and 80 A]
Replacement of brushes
Assemblage [Type 60 A]
Assemblage [Type 70 A and 80 A]
+ Specifications
The inhaling moments
+ Tools/information for drivers
|
Survey [Type 70 A and 80 A]
Rotor
|
|
- Using an ohmmeter, check up electroconductivity between contact rings of a rotor. If there is no electroconductivity, replace a rotor. Standard resistance: nearby 2.9.
|
|
- Using an ohmmeter, check up, whether there is no electroconductivity between contact rings and a rotor. If there is an electroconductivity, replace a rotor.
|
- Check up contact rings, whether there is no roughness or a deposit. If they rough or are a deposit, replace a rotor.
|
- Using a calliper with нониусом, measure diameter of a contact ring.
- Standard diameter: 14.2-14.4 mm (0.557 - 0.567 inches)
- The minimum diameter: 12.8 mm (0.504 inches)
|
- If diameter less minimum, replace a rotor.
|
|
Статор
|
|
- Using an ohmmeter, check up electroconductivity of all contacts. If there is no electroconductivity, replace статор.
|
|
- Using an ohmmeter, check up, whether there is no electroconductivity between contacts статора and the core статора. If there is an electroconductivity, replace статор.
|
|
|
Brush and щеткодержатель
|
Check up each brush on deterioration, having measured its length, as shown. If the brush is worn out to a limit, replace a brush. Address to Section Replacement of brushes in this Chapter.
- Length of an open part of a brush "a":
- The standard: 10.5 mm (0.413 inches)
- Limit: 4.5 mm (0.351 inches)
|
The rectifier
The positive rectifier
|
- Using an ohmmeter, connect one щуп a tester to plug "B", and another – to each of rectifier plugs.
- Replace polarity щупов a tester and repeat item 1.
- Check up that one shows conductivity presence, and another – is not present.
- If there is an electroconductivity, replace the rectifier.
|
1 — plug "B" 2 — the rectifier plug |
|
|
The negative rectifier
|
- Using an ohmmeter, connect one щуп a tester to each of negative contacts, and another to each of rectifier plugs.
- Replace polarity щупов a tester and repeat item 1.
- Check up that one shows conductivity presence, and another – is not present.
- If there is an electroconductivity, replace the rectifier.
|
1 — negative contact 2 — the rectifier plug |
|
|
The bearing
|
|
- Check up that the drive and the bearing has no jags and are not worn out.
|
|
- Check up that the casing of the bearing has no jags and is not worn out.
|
|
|
|
|